P1 Single Bubble Foil White

Typeresidentialcommercial
LeafletApplications
FloorBasementWallMetal BuildingBarndominiumCarport
Features
- 5-layer bubble insulation structure
- Solid poly white surface for a clean, aesthetic finish
- Low-emittance foil surface (E=5%)
- Reflects 95% of radiant heat
- Unique LDPE plastics blend for long service life
- Stiffer than most bubbles on the market, allowing easier installation
- Suitable for all building insulation applications
- Ideal for retrofits and home improvement projects
- Excellent insulation for metal buildings and carports
- Minimizes heat bridges in metal structures
- Will not delaminate, ensuring durability and stability
- Compatible with hybrid installations using foam or fiberglass
- Ideal for metal buildings requiring a white facing
- Provides an impressive R-value when installed with an airspace
Variants
| Name | SKU | Roll Size | Width | Length | Weight |
|---|---|---|---|---|---|
| 500 ft² | SB-4mmWB-FW | 500 sq ft | 48" | 125' | 31 lbs |
| Eco 635 ft² Woven | SB-3mmWB-FWV ST | 635 sq ft | 61" | 125' | 38 lbs |
Specifications
| Specification | Value |
|---|---|
| Standard Roll Sizes | 48"x125' / 61"x125' |
| Effective Coverage | 500 ft² / 635 ft² |
| Thickness (inches) ±5% | 0.16" nominal |
| Standard Roll Weight (lbs) ±5% | 31 lb / |
| Emittance (Metalized Foil Side) | E=5% (95% Reflective) |
| Water Vapor Transmission ASTM E-96 | 0.02 perms |
| Mold and Mildew | No Growth |
| Flame Spread, Smoke Development, Fire Rating | Class A / Class 1 |
Thermal Performance
| Assembly | Heat-Flow Direction | Typical R-Value |
|---|---|---|
| Crawl Space | R-5.5 | |
| Metal Buildings | Heat flow down | R-4.2 to R-17.1 |
| Metal Buildings | Heat flow horizontal | R-2.2 to R-6.1 |
| Post Frame Buildings | Heat flow down | R-4.2 to R-17.1 |
| Post Frame Buildings | Heat flow horizontal | R-2.2 to R-6.1 |
| Radiant Floors | Heat flow down | R-4.2 to R-17.1 |
| Wall - Basement Masonry | Heat flow horizontal | R-2.2 to R-6.1 |
- R-values represent estimated and potential heat resistance for our insulation in the proposed application.
- Actual performance depends on air film size, temperature, surface condition, and airflow direction (up, down, or horizontal).
- Calculations are based on RIMA, AIRAH, ASHRAE, and ISO 6946 standards, following ASTM procedures for air film resistance.
- When two air spaces are used, values assume still air conditions in both spaces.
- For a full R-value assessment, please contact us directly or your nearest dealer.